Shrnutí obsahu

Strany 1 - User’s Guide

NuDAQ 6208/6216 Series Multi-channel Analog Output Cards User’s Guide Recycle Paper

Strany 2

2 • Introduction 1.1 Features • 32-bit cPCI/PCI-Bus, Plug and Play • 16-bit high resolution voltage outputs • Output Range: ±10V (14-bit resolut

Strany 3

Introduction • 3 • Differential Linearity Error: ± 0.001 % Full Scale Range • Output initial status: 0V (after RESET or POWER-ON) • Data Transfer:

Strany 4 - Getting service from ADLINK

4 • Introduction ♦ General Specifications • Operating temperature: 0° ~ 50°C • Storage temperature: -20° ~ 80°C • Humidity: 5~95% non-condensing •

Strany 5 - Table of Contents

Introduction • 5 1.4 Supporting Software ADLINK provides versatile software drivers and packages for users’ different approach to building a system.

Strany 6

6 • Introduction 1.4.2 PCIS-LVIEW: LabVIEW® Driver PCIS-LVIEW contains the VIs, which are used to interface with NI’s PCIS-LVIEW contains the VIs, wh

Strany 7 - Tables and Figures

Introduction • 7 1.4.7 PCIS-ISG: ISaGRAFTM driver The ISaGRAF Workbench is an IEC1131-3 SoftPLC control development environment. The PCIS-ISG include

Strany 8 - How to Use This Guide

8 • Getting Started 2 Getting Started This chapter describes how to install and setup the cPCI/PCI-6208. The contents in the package and unpacking inf

Strany 9 - Introduction

Getting Started • 9 2.2 Unpacking The 6208 card contains electro-static sensitive components that can be easily be damaged by static electricity. The

Strany 10 - 1.3 Specifications

10 • Getting Started 2.3 PCB Layout Figure 1: PCI-6208 REV: A3 Layout

Strany 11

Getting Started • 11 Figure 2: PCI-6208 REV: B1 Layout Optional DC-DC Converter

Strany 13 - 1.4 Supporting Software

12 • Getting Started Figure 3: cPCI-6208 Layout

Strany 14

Getting Started • 13 Figure 4: cPCI-6208V/R Layout

Strany 15 - 1.4.8 PCIS-ICL: InControl

14 • Getting Started Figure 5: cPCI-R6216DB Rear I/O Adapter for cPCI-6208V/R, cPCI-6208A/R and cPCI-6216V/R

Strany 16 - Getting Started

Getting Started • 15 2.4 Connector Pin Assignment The pin assignment of the 6208 series card is shown in Figure 2.2 DI3DI2DI1DI0GND+5V+15VA.GNDV14(

Strany 17 - 2.2 Unpacking

16 • Getting Started 2.5 Hardware Installation Outline Hardware configuration The PCI cards (or CompactPCI cards) are equipped with plug and play PCI

Strany 18 - 2.3 PCB Layout

Getting Started • 17 2.6 Device Installation for Windows Systems Once Windows 95/98/2000 has started, the Plug and Play functions of the Windows syst

Strany 19

18 • Registers 3 Registers The detailed descriptions of the registers format are specified in this chapter. This information is quite useful for the

Strany 20 - 12 • Getting Started

Registers • 19 3.2 I/O Address Map Depending on which card is used, either the cPCI/PCI-6208V or PCI-6216V, there are 8 or 16 voltage output channels

Strany 21 - Getting Started • 13

20 • Registers 3.3 Analog Output Status Register The DAC uses a series bus architecture hence it will take time for digital value to be sent out. Th

Strany 22

Operation Theory • 21 4 Operation Theory In this chapter, the operation theory of the 6208 series cards is described. Before programming or applying t

Strany 23

©Copyright 2002 ADLINK Technology Inc. All Rights Reserved. Manual Rev. 3.22: September 13, 2002 Part No.: 50-12201-005 The information in this docum

Strany 24

22 • Operation Theory 4.2 Current Output The precision voltage-to-current converter XTR110 implements the current output. The current output channel

Strany 25

C/C++ Library • 23 5 C\C++ Library This chapter describes the software libraries for operating this card. Only the functions in the DOS library and Wi

Strany 26 - Registers

24 • C/C++ Library 5.2 Programming Guide 5.2.1 Naming Convention The functions of the NuDAQ PCI or NuIPC CompactPCI card software drivers uses full

Strany 27 - 3.2 I/O Address Map

C/C++ Library • 25 5.3 _6208_Initial @ Description This function is used to initialize the 6208 series cards. You must call this function to initiali

Strany 28 - 3.5 Digital Input Register

26 • C/C++ Library 5.4 _6208_Software_Reset @ Description This function is used to reset the I/O ports configuration. Note that this function will no

Strany 29 - Operation Theory

C/C++ Library • 27 5.5 _6208_DA @ Description This function is used to write data to the D/A converters. There are 8 or 16 Digital-to-Analog convers

Strany 30 - 4.2 Current Output

28 • C/C++ Library 5.6 _6208_Get_DA_Status @ Description This function is used to check the DA data sending status. Because the data transfer time f

Strany 31 - C\C++ Library

C/C++ Library • 29 5.7 _6208_DI @ Description This function is used to read data from the digital input ports. There are 4 digital input channels on

Strany 32 - 5.2 Programming Guide

30 • C/C++ Library 5.8 _6208_DO @ Description This function is used to write data to digital output ports. There are 4 digital output channels on 620

Strany 33 - 5.3 _6208_Initial

C/C++ Library • 31 5.9 _6208_I2V_Control @ Description This function is used to set the cPCI/PCI-6208A voltage-to-current mode control. There are t

Strany 34 - 5.4 _6208_Software_Reset

Getting service from ADLINK • Customer Satisfaction is the most important priority for ADLINK Tech Inc. If you need any help or service, please cont

Strany 35 - 5.5 _6208_DA

32 • Utility/Calibration 6 Utility / Calibration The software CD provides a utility program, 6208util.exe, and is intended for calibration and functio

Strany 36 - 5.6 _6208_Get_DA_Status

Utility/Calibration • 33 6.1.1 Functional Testing This function is used to test the D/A functions of the cPCI/PCI-6208V /6208A /6216V. When you choo

Strany 37 - 5.7 _6208_DI

34 • Utility/Calibration 6.1.2 Calibration This function guides you through on how to calibrate the 6208 series card. The calibration program can ser

Strany 38 - 5.8 _6208_DO

Utility/Calibration • 35 Figure 13: Channel Selection Menu After you have selected a channel from the channel selection menu, a calibration proce

Strany 39 - 5.9 _6208_I2V_Control

36 • Utility/Calibration 6.2.2 VR Assignment of cPCI/PCI-6208 and PCI-6216 There are either 8 or 16 voltage output channels depending on which model

Strany 40 - Utility / Calibration

Utility/Calibration • 37 6.2.3 Voltage Output Calibration Because there is an internal reference voltage for each DA channel, the calibration process

Strany 41 - 6.1.1 Functional Testing

38 • Warranty Policy Warranty Policy Thank you for choosing ADLINK. To understand your rights and enjoy all the after-sales services we offer, plea

Strany 42 - 6.1.2 Calibration

Warranty Policy • 39 5. To ensure the speed and quality of product repair, please download an RMA application form from our company website www.adlin

Strany 43 - 6.2.1 What You Need

Table of Contents • i Table of Contents Tables and Figures ...iii How to Use This Guide...

Strany 44

ii • Table of Contents Operation Theory...21 4.1 Voltage Output ...

Strany 45

Tables and Figures • iii Tables and Figures Tables Table 1. I/O Address Map ... 19 Table 2. Digi

Strany 46 - Warranty Policy

iv • How to Use This Guide How to Use This Guide This manual is designed to help you use the 6208 series products. It describes how to modify and cont

Strany 47

Introduction • 1 1 Introduction The 6208 series products are multi-channel analog output cards. They include the following three products: • cPCI/PCI