12 Getting Started
Figure 2-3: Latching the cPCI module handles securely.
5. Push inwards on the handles for final insertion. Ensure
that the buttons on the handles fully latch into position as
unless this is done the card is not correctly inserted. Fas-
ten the retaining screws at each end of the card (2 for
single slot cards, 4 for double slot cards).
6. To remove the module, undo the retaining screws, press
the release buttons (if necessary), and reverse steps 1
through 5 above.
CompactPCI PSU Installation/Removal Procedure
The cPCIS-3320 Series come with cPS-H325 PSUs pre-installed.
The removal and installation procedures for PSUs are the same
as for CompactPCI cards, except there is only one handle. To
replace a PSU module, refer to the figures and instructions below.
1. To remove the PSU module, undo the retaining screws
and unlatch the handle by pressing on the release but-
ton.
Zobrazit stránku 19